防爆组合式空调机组参数 |
风量CMH |
余压Pa |
四排冷量KW |
六排冷量Kw |
二排热水加热量KW |
蒸汽加热量KW |
电加热量KW |
电极加湿量kg/h |
电极功率KW |
6000 |
500 |
37.2 |
45.5 |
40 |
78 |
18 |
10 |
3 |
|
8000 |
500 |
50.5 |
62.7 |
52 |
104 |
24 |
13 |
4 |
|
10000 |
600 |
60.3 |
78.6 |
65 |
130 |
30 |
13 |
5.5 |
|
12000 |
600 |
72.9 |
94.6 |
80 |
156 |
36 |
15 |
5.5 |
|
15000 |
600 |
98.5 |
119.2 |
98 |
195 |
45 |
15 |
7.5 |
|
18000 |
600 |
118.2 |
143.0 |
120 |
234 |
54 |
25 |
11 |
|
20000 |
700 |
139.4 |
167.7 |
130 |
260 |
60 |
30 |
11 |
|
23000 |
700 |
145.5 |
185.5 |
150 |
300 |
60 |
30 |
11 |
|
25000 |
700 |
169.4 |
203.5 |
163 |
325 |
72 |
45 |
15 |
|
28000 |
700 |
185.4 |
225.8 |
182 |
364 |
72 |
45 |
15 |
|
30000 |
700 |
199.2 |
239.6 |
195 |
39 |
75 |
45 |
15 |
|
35000 |
800 |
235.6 |
283.6 |
225 |
450 |
90 |
60 |
18.5 |
|
40000 |
800 |
271.1 |
325.6 |
260 |
520 |
100 |
60 |
22 |
|
45000 |
800 |
286.1 |
372.1 |
290 |
580 |
108 |
60 |
30 |
|
50000 |
800 |
322.6 |
419.8 |
325 |
650 |
120 |
75 |
30 |
|
55000 |
800 |
355.6 |
448.6 |
355 |
715 |
132 |
75 |
30 |
|
60000 |
800 |
382.9 |
467.4 |
390 |
780 |
144 |
90 |
37 |
产品特点:节能环保、简单可靠、操作简单,运行噪音低,便于维护。采用485协议控制,符合工业编程要求,满足互联网远程控制需求。
适用范围:可应用于可燃气体、粉尘、遇火或过热物体甚至至于爆炸的环境中,也可广泛应用于制药厂、医疗卫生、生物工程、食品饮料、电子工业等对空气有洁净度及空调要求的场所。
适用范围:
1.本产品适用于石油化工、冶金、纺织、食品、生物工程、制药、仓库、航天航空工程等爆炸性环境中,有温度控制要求的场所;
2.1区、2区危险气体场所
3.IIA、IIB、IIC类T1-T4组爆炸性气体或蒸汽环境;
4.环境温度:-5℃~+43℃。
本系列产品执行标准如下:
GB3836.1-2010《爆炸性环境 第1部分:设备通用要求》
GB3836.2-2010《爆炸性环境 第2部分:由隔爆外壳“d”保护的设备》
GB3836.4-2010《爆炸性环境 第4部分:由本质安全型“i”保护的设备》
GB3836.9-2006《爆炸性气体环境用电气设备 第9部分:浇封型“m”》
GB3836.15-2000《爆炸性气体环境用电气设备 第15部分:危险场所电气安装(煤矿除外)》
在下列环境条件下能正常工作:
a.海拔不超过2000m;
b.适用环境为:温度5℃~43℃,无腐蚀性气体;
c.存在ⅡA、ⅡB级,T1~T4组可燃性气体、蒸汽与空气混合形成的爆炸危险场所。