品牌:英鹏
名称
|
防爆组合风柜系列
|
风机段
|
风量(M³/H)
|
2000
|
3000
|
4000
|
5000
|
6000
|
7000
|
8000
|
9000
|
10000
|
机外静压Pa
|
200
|
300
|
300
|
300
|
400
|
400
|
400
|
500
|
500
|
电机功率KW
|
1.1
|
1.5
|
1.5
|
2.2
|
3
|
3
|
4
|
5.5
|
5.5
|
表冷段
|
新风冷量KW
|
4RX
|
24
|
36
|
48
|
60
|
72
|
84
|
96
|
108
|
120
|
6RX
|
31.2
|
46.8
|
62.4
|
78
|
93.6
|
109.2
|
124.8
|
140.4
|
156
|
8RX
|
34
|
51
|
68
|
85
|
102
|
119
|
136
|
153
|
170
|
冷冻水管径DN/4RX
|
32
|
32
|
40
|
40
|
50
|
50
|
50
|
65
|
65
|
冷冻水管径DN/6RX
|
32
|
40
|
50
|
50
|
50
|
65
|
65
|
65
|
80
|
冷冻水管径DN/8RX
|
32
|
40
|
50
|
50
|
50
|
65
|
65
|
65
|
80
|
冷水流量(M³/H)4RX
|
4.13
|
6.19
|
8.26
|
10.32
|
12.38
|
14.45
|
16.51
|
18.58
|
20.64
|
冷水流量(M³/H)6RX
|
5.37
|
8.05
|
10.73
|
13.42
|
16.10
|
18.78
|
21.47
|
24.15
|
26.83
|
冷水流量(M³/H)8RX
|
5.85
|
8.77
|
11.70
|
14.62
|
17.54
|
20.47
|
23.39
|
26.32
|
29.24
|
加热段
|
热水加热量KW
|
24
|
36
|
48
|
60
|
72
|
84
|
96
|
108
|
120
|
热水管径DN
|
32
|
32
|
40
|
40
|
50
|
50
|
50
|
65
|
65
|
电加热补偿量KW
|
8
|
10
|
15
|
18
|
20
|
25
|
30
|
30
|
35
|
加湿段
|
电极加湿量KG/H
|
13
|
19
|
25
|
32
|
38
|
44
|
50
|
57
|
63
|
干蒸汽加湿量
|
电流
|
380V/3P/50Hz
|
最大功率
|
KW
|
19
|
26
|
35
|
44
|
51
|
61
|
72
|
78
|
88
|
最大电流
|
A
|
35
|
49
|
67
|
83
|
98
|
116
|
136
|
148
|
167
|
机组噪声db
|
≤65
|
≤65
|
≤65
|
≤65
|
≤70
|
≤70
|
≤70
|
≤70
|
≤70
|
防爆标志
|
ExdbibmbIIBT4Gb
|
名称
|
防爆组合风柜系列
|
风机段
|
风量(M³/H)
|
11000
|
12000
|
13000
|
14000
|
15000
|
16000
|
17000
|
18000
|
19000
|
机外静压Pa
|
500
|
500
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
电机功率KW
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
11
|
11
|
11
|
表冷段
|
新风冷量KW
|
4RX
|
132
|
144
|
156
|
168
|
180
|
192
|
204
|
216
|
228
|
6RX
|
171.6
|
187.2
|
202.8
|
218.4
|
234
|
249.6
|
265.2
|
280.8
|
296.4
|
8RX
|
187
|
204
|
221
|
238
|
255
|
272
|
289
|
306
|
323
|
冷冻水管径DN/4RX
|
65
|
65
|
80
|
80
|
80
|
80
|
80
|
80
|
80
|
冷冻水管径DN/6RX
|
80
|
80
|
80
|
80
|
80
|
80
|
100
|
100
|
100
|
冷冻水管径DN/8RX
|
80
|
80
|
80
|
80
|
100
|
100
|
100
|
100
|
100
|
冷水流量(M³/H)4RX
|
22.70
|
24.77
|
26.83
|
28.90
|
30.96
|
33.02
|
35.09
|
37.15
|
39.22
|
冷水流量(M³/H)6RX
|
29.52
|
32.20
|
34.88
|
37.56
|
40.25
|
42.93
|
45.61
|
48.30
|
50.98
|
冷水流量(M³/H)8RX
|
32.16
|
35.09
|
38.01
|
40.94
|
43.86
|
46.78
|
49.71
|
52.63
|
55.56
|
加热段
|
热水加热量KW
|
132
|
144
|
156
|
168
|
180
|
192
|
204
|
216
|
228
|
热水管径DN
|
65
|
65
|
80
|
80
|
80
|
80
|
80
|
80
|
80
|
电加热补偿量KW
|
40
|
42
|
45
|
50
|
52
|
55
|
60
|
63
|
65
|
加湿段
|
电极加湿量KG/H
|
69
|
76
|
82
|
88
|
95
|
101
|
107
|
113
|
120
|
干蒸汽加湿量
|
电流
|
380V/3P/50Hz
|
最大功率
|
KW
|
99
|
106
|
114
|
124
|
130
|
138
|
151
|
159
|
166
|
最大电流
|
A
|
189
|
202
|
217
|
235
|
248
|
262
|
288
|
302
|
315
|
机组噪声db
|
≤72
|
≤72
|
≤74
|
≤76
|
≤74
|
≤78
|
≤76
|
≤78
|
≤78
|
防爆标志
|
ExdbibmbIIBT4Gb
|
名称
|
防爆组合风柜系列
|
风机段
|
风量(M³/H)
|
20000
|
22000
|
25000
|
28000
|
30000
|
35000
|
40000
|
45000
|
50000
|
机外静压Pa
|
700
|
700
|
700
|
700
|
700
|
800
|
800
|
800
|
900
|
电机功率KW
|
11
|
11
|
15
|
15
|
15
|
18.5
|
22
|
30
|
30
|
表冷段
|
新风冷量KW
|
4RX
|
240
|
264
|
300
|
336
|
360
|
420
|
480
|
540
|
600
|
6RX
|
312
|
343.2
|
390
|
436.8
|
468
|
546
|
624
|
702
|
780
|
8RX
|
340
|
374
|
425
|
476
|
510
|
595
|
680
|
765
|
850
|
冷冻水管径DN/4RX
|
100
|
100
|
100
|
100
|
100
|
125
|
125
|
125
|
150
|
冷冻水管径DN/6RX
|
100
|
100
|
125
|
125
|
125
|
150
|
150
|
150
|
150
|
冷冻水管径DN/8RX
|
100
|
100
|
125
|
125
|
125
|
150
|
150
|
150
|
150
|
冷水流量(M³/H)4RX
|
41.28
|
45.41
|
51.60
|
57.79
|
61.92
|
72.24
|
82.56
|
92.88
|
103.20
|
冷水流量(M³/H)6RX
|
53.66
|
59.03
|
67.08
|
75.13
|
80.50
|
93.91
|
107.33
|
120.74
|
134.16
|
冷水流量(M³/H)8RX
|
58.48
|
64.33
|
73.10
|
81.87
|
87.72
|
102.34
|
116.96
|
131.58
|
146.20
|
加热段
|
热水加热量KW
|
240
|
264
|
300
|
336
|
360
|
420
|
480
|
540
|
600
|
热水管径DN
|
100
|
100
|
100
|
100
|
100
|
125
|
125
|
125
|
150
|
电加热补偿量KW
|
70
|
75
|
90
|
100
|
105
|
125
|
140
|
160
|
175
|
加湿段
|
电极加湿量KG/H
|
126
|
139
|
158
|
176
|
189
|
221
|
252
|
284
|
315
|
干蒸汽加湿量
|
电流
|
380V/3P/50Hz
|
最大功率
|
KW
|
176
|
190
|
223
|
247
|
262
|
309
|
351
|
403
|
441
|
最大电流
|
A
|
334
|
361
|
424
|
470
|
497
|
587
|
667
|
765
|
839
|
机组噪声db
|
≤79
|
≤79
|
≤80
|
≤80
|
≤82
|
≤82
|
≤82
|
≤84
|
≤84
|
防爆标志
|
ExdbibmbIIBT4Gb
|
名称
|
防爆组合风柜系列
|
风机段
|
风量(M³/H)
|
55000
|
60000
|
70000
|
80000
|
90000
|
100000
|
120000
|
机外静压Pa
|
900
|
900
|
900
|
1000
|
1200
|
1200
|
1300
|
电机功率KW
|
30
|
37
|
22×2
|
30×2
|
30×2
|
37×2
|
30×3
|
表冷段
|
新风冷量KW
|
4RX
|
660
|
720
|
840
|
960
|
1080
|
1200
|
1440
|
6RX
|
858
|
936
|
1092
|
1248
|
1404
|
1560
|
1872
|
8RX
|
935
|
1020
|
1190
|
1360
|
1530
|
1700
|
2040
|
冷冻水管径DN/4RX
|
150
|
150
|
150
|
200
|
200
|
200
|
200
|
冷冻水管径DN/6RX
|
150
|
200
|
200
|
200
|
200
|
200
|
200
|
冷冻水管径DN/8RX
|
150
|
200
|
200
|
200
|
200
|
200
|
200
|
冷水流量(M³/H)4RX
|
113.52
|
123.84
|
144.48
|
165.12
|
185.76
|
206.40
|
247.68
|
冷水流量(M³/H)6RX
|
147.58
|
160.99
|
187.82
|
214.66
|
241.49
|
268.32
|
321.98
|
冷水流量(M³/H)8RX
|
160.82
|
175.44
|
204.68
|
233.92
|
263.16
|
292.40
|
350.88
|
加热段
|
热水加热量KW
|
660
|
720
|
840
|
960
|
1080
|
1200
|
1440
|
热水管径DN
|
150
|
150
|
150
|
200
|
200
|
200
|
200
|
电加热补偿量KW
|
195
|
210
|
245
|
285
|
315
|
350
|
420
|
加湿段
|
电极加湿量KG/H
|
347
|
378
|
441
|
504
|
567
|
630
|
756
|
干蒸汽加湿量
|
电流
|
|
|
|
|
|
|
|
最大功率
|
KW
|
485
|
531
|
620
|
723
|
800
|
897
|
1077
|
最大电流
|
A
|
921
|
1008
|
1178
|
1374
|
1521
|
1704
|
2047
|
机组噪声db
|
≤83
|
≤85
|
≤86
|
≤89
|
≤90
|
≤89
|
≤92
|
防爆标志
|
ExdbibmbIIBT4Gb
|
产品介绍:
组合风柜机组,采用先进优良的架构工艺,多种技术措施相结合。确保风柜机组噪音低、能效高、外形轻巧、安装方便、安全无凝露。机组配置灵活多变。按功能需求,配置混合、过滤、冷却、加热、加湿、除湿、热回收、消毒的等空气处理功能段组合。
产品特点:
1、盘管采用电脑选型优化设计,对制冷效能及空气、水压力损耗合理选配。制冷盘管、热水盘管和蒸汽盘管为无缝紫铜管+铝翅片材质。盘管底部冷凝水盘为不锈钢材质的满布式折坡干式水盘,确保冷凝水排放畅通,使水盆始终为干式,减少病菌滋生。
2、混合段的空间,使新、回风混合均匀、充分。新回风风口可配置调节阀,材质为铝合金,调节阀采用人字对开型。叶片是双面机翼型结构,铝合金叶片边缘带密封胶条互锁,风阻低、漏风率小。
3、根据风量与静压值的要求,电脑软件选配一台或多台离心风机。采用知名品牌双进风离心式高效前倾或后倾风机,具有低噪音、高效率、运转平稳、振动小、强度好、轴承温升低、工作温度湿度范围大等优点。风机的传动形式主要采用外转子直接传动和皮带传动两种形式。标准配置的电机选用优质名牌电机,运转畅顺,噪声低,使用寿命长。
4、常用加湿器型式包括:干蒸汽加湿器、电极式加湿器、高压喷雾加湿器、湿膜加湿器等,以上加湿型式均可实现洁净加湿,前两种为等温加湿,后两种为等焓加湿。
5、加热方式有热水盘管加热、蒸汽盘管加热、电加热三种方式。电加热分为不锈钢管绕不锈钢翅片电加热和PTC电加热两种。电加热必须在通风情况下才能通电使用,电加热器与通风机要有启闭的连锁装置,而且必须设有双重超热保护,确保其使用安全。
适用范围:可应用于可燃气体、粉尘、遇火或过热物体甚至至于爆炸的环境中,也可广泛应用于制药厂、医疗卫生、生物工程、食品饮料、电子工业等场所。